Equipment Details
Pump Make & Model
Becker SV400/1
Serial Number: 2950156

Fault Diagnosis
The pump has failed due to being operated without an air filter. As a result, it has ingested dirty air over time, leading to the accumulation of contaminants within the internal components. This contamination has caused significant internal wear and damage.
Cause of Failure
Operation without an air filter, resulting in the intake of dirty air and subsequent internal damage.
Recommendation
To prevent future failures and ensure clean air intake, we strongly recommend the installation of an external POD filter.
Repair Scope
- Full strip-down and internal cleaning of the pump
- Replacement of all worn bearings and seals
- Replacement of broken or missing components including:
- Fan
- Fan cover
- Terminal box
- Reassembly of the unit with new parts
- Functional testing to verify operational performance
- Final painting and preparation for delivery
Notes
The absence of adequate filtration has significantly compromised the integrity of this pump. Going forward, proper filtration must be in place to maintain pump performance and longevity.
Conclusion
The client has approved the repair and requested the installation of the external POD filter. The pump was successfully repaired, tested for performance, and prepared for dispatch.